CEMS by Uncloud БГ Open CEMS

Solis inverters, curtailed on the day-ahead price and read back off the hardware to prove it landed.

CEMS talks to Solis through SolisCloud, over Ginlong's own control interface. No gateway on site, no local Modbus, no second box in the cabinet — the same credentials your installer already has are enough. What follows is what CEMS does with them, what it can prove afterwards, and where the limits are.

Cloud
SolisCloud
Credentials
KeyID + KeySecret
Granularity
Per inverter
Range
0 – 110% of rated
Read-back
Verified against hardware

The control path

Curtailment, not shutdown.

CEMS derates a Solis inverter to a percentage of its rated power, and restores it by setting that percentage back to full. Nothing is turned off and nothing has to be started again.

What CEMS reads

Every string, every inverter, every five minutes.

Telemetry CEMS collects from SolisCloud
Reading Level
Active powerPlant and inverter
Energy today, this month, this year, lifetimePlant
Energy today and lifetimeInverter
Inverter temperatureInverter
Operating stateInverter
DC voltage and current, per stringUp to 32 strings

Before it can work

Two keys, and one switch on your SolisCloud account.

  1. 01

    Have API management enabled

    SolisCloud does not expose the API to every account by default. It is enabled on the account, by Solis, on request — usually through whoever commissioned the plant. Without it the credentials exist but the API does not answer to them yet.

  2. 02

    Generate a KeyID and KeySecret

    From the SolisCloud portal, on the account that owns the plants. These are account-wide: one pair reaches every station and every inverter that account can see, which is why CEMS never asks for your portal password.

  3. 03

    Paste them into CEMS once

    They are encrypted before they are stored and never held in the clear. Your plants then appear on their own, with their inverters under them, and you pick which ones CEMS should look after.

  4. 04

    Rehearse before you arm

    A new plant starts in dry run. The engine decides exactly as it would in earnest and writes the audit row it would have written in normal operation, but sends no command to the inverter. You can watch it rehearse for a few days, then switch it to active control.

Read this if anything else already reaches your inverters

Anything else that sets this limit will fight CEMS.

An inverter is shared infrastructure. A site EMS, an installer's app, a controller in the cabinet, a home automation box, a Modbus script somebody wrote two years ago — any of them with the credentials can write the same power limit, and none of them announce it.

Which is the honest answer, not the comfortable one: turn the other automation off for the plants CEMS looks after. Two systems commanding one register is not a configuration, it is a race.

Questions

Questions owners ask.

Can Solis inverters be curtailed remotely?

Yes. CEMS sets an active power limit on each Solis inverter through SolisCloud, anywhere from 0 to 110% of rated, and reads it back off the hardware after every command. Nothing is installed on site.

When does CEMS curtail them?

When the day-ahead price for your bidding zone — in Bulgaria, the IBEX day-ahead market — turns negative or falls under the floor you set. When the price recovers, the inverters go back to full output.

What does it cost?

Each inverter is €65 a year, excluding VAT, and the first 30 days are free. See pricing.

Stop selling energy at a loss. Connect your Solis plant and try it without risk.

A new plant starts in dry run: CEMS makes every decision it would make in earnest and sends nothing, so you see exactly what it would do before it does it.