Huawei inverters, curtailed on the day-ahead price and confirmed on the hardware, one inverter at a time.
CEMS curtails Huawei inverters on the day-ahead price and watches them between times. No gateway on site, no local Modbus, no second box in the cabinet — it connects to your existing FusionSolar account. What follows is what it does, what it needs, and where the limits are.
- Cloud
- FusionSolar
- Access
- Installer account
- Granularity
- Per inverter
- Range
- 0 – 100% of rated
- Read-back
- Verified against hardware
What CEMS does
A limit, not a shutdown.
CEMS holds a Huawei inverter at a percentage of its rated power while the price is below your threshold, and returns it to full when the price recovers. Nothing is switched off and nothing has to be restarted.
Anything between 0 and 100% of rated is available. Both directions have been confirmed on real hardware, on a real site.
What CEMS reads
Every inverter, every five minutes.
Active power, the day's energy, lifetime yield and internal temperature, for each inverter and for the plant. Alongside it, the day-ahead price for your bidding zone, so production and what it was worth sit on the same chart.
Before it can work
One account, and a rehearsal.
-
01
A FusionSolar account with installer rights
Watching a plant and changing a setting on it are different levels of access. Curtailment needs the second. A viewer login is enough to monitor a site and not enough to control it.
-
02
Connect it to CEMS once
Credentials are encrypted before they are stored and never held in the clear. Your plants then appear on their own, with their inverters under them, and you pick which ones CEMS should look after.
-
03
Check what else controls the inverters
An existing export cap, a grid operator's scheduling or a derating left over from commissioning are all legitimate reasons for an inverter to sit below nameplate. Where two systems set the same limit, decide which one owns it before arming the plant.
-
04
Rehearse before you arm
A new plant starts in dry run. The engine decides exactly as it would in earnest and writes the audit row it would have written in normal operation, but sends no command to the inverter. You can watch it rehearse for a few days, then switch it to active control.
Questions
Questions owners ask.
Can Huawei inverters be curtailed remotely?
Yes. CEMS sets an active power limit on each Huawei inverter through FusionSolar, anywhere from 0 to 100% of rated, and confirms it on the hardware. It needs a FusionSolar account with installer rights; nothing is installed on site.
When does CEMS curtail them?
When the day-ahead price for your bidding zone — in Bulgaria, the IBEX day-ahead market — turns negative or falls under the floor you set. When the price recovers, the inverters go back to full output.
What does it cost?
Each inverter is €65 a year, excluding VAT, and the first 30 days are free. See pricing.
Stop selling energy at a loss. Connect your Huawei plant and try it without risk.
Huawei is one of the makes that work with CEMS most fully and reliably. A new plant starts in dry run: CEMS makes every decision it would make in earnest and sends nothing, so you see exactly what it would do before it does it.