RENAC inverters, curtailed on the day-ahead price down to 2% of rated, so the inverter never switches itself off.

CEMS reaches RENAC through RENAC SEC, the manufacturer's own cloud. No gateway on site, no local Modbus, no second box in the cabinet. What follows is what CEMS commands, what it reads and what it needs from you.

Cloud
RENAC SEC
Credentials
Account and password
Granularity
Per inverter
Range
2 – 100% of rated
Read-back
Verified against hardware

The control path

A limit, not a shutdown — and the difference is not academic here.

CEMS holds a RENAC inverter at a percentage of its rated power while the price is under your floor, and returns it to full when the price recovers. The limit belongs to one inverter and is addressed by that inverter's serial number, so a plant with two machines is two commands and two separate sets of books.

Proven on real hardware on 9 September 2026, on two 30 kW machines: commanded down, held there against measured production for a quarter of an hour, and released. Twice, in daylight, with the meter watched throughout.

What CEMS reads

Every string, every inverter, every five minutes.

Telemetry CEMS collects from RENAC SEC
Reading Level
Active powerPlant and inverter
Energy today, this month, this year and lifetimePlant
Energy today and lifetimeInverter
Grid frequency and phase voltagesInverter
Inverter temperatureInverter
Operating stateInverter
DC voltage, current and power, per stringInverter

Before it can work

The account you already have, and the right region.

  1. 01

    Use the RENAC account that monitors the plants

    The same account and password used at the RENAC SEC portal. There is nothing to request from the manufacturer, no developer application, and no key to wait for.

  2. 02

    Pick the region the account was created in

    Europe, Asia or America. The three deployments do not share data, and the wrong one refuses a perfectly correct password.

  3. 03

    Import only the plants you look after

    An installer login lists every plant that installer commissioned, including other owners'. Only the plants you import are ever polled, and only the ones you arm are ever commanded.

  4. 04

    Rehearse in daylight

    A new plant starts in dry run, deciding exactly as it would in earnest and sending nothing. Watch it through a few price hours before arming it — and arm it in daylight, because that is the only time this hardware can answer.

Read this if anything else already reaches your inverters

Anything else that sets this limit will fight CEMS.

An inverter is shared infrastructure. A site controller, an installer's app, the manufacturer's own portal, a script somebody wrote two years ago — any of them with access can move the same power limit, and none of them announce it.

Which is the honest answer rather than the comfortable one: turn the other automation off for the plants CEMS looks after. Two systems commanding one setting is not a configuration, it is a race.

Questions

Questions owners ask.

Can RENAC inverters be curtailed remotely?

Yes. CEMS sets an active power limit on each RENAC inverter through RENAC SEC, anywhere from 2 to 100% of rated — 2% rather than zero, so the inverter never switches itself off — and reads it back off the hardware. Nothing is installed on site.

When does CEMS curtail them?

When the day-ahead price for your bidding zone — in Bulgaria, the IBEX day-ahead market — turns negative or falls under the floor you set. When the price recovers, the inverters go back to full output.

What does it cost?

Each inverter is €65 a year, excluding VAT, and the first 30 days are free. See pricing.

Stop selling energy at a loss. Connect your RENAC plant and try it without risk.

A new plant starts in dry run: CEMS makes every decision it would make in earnest and sends nothing, so you see exactly what it would do before it does it.